Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arq. bras. cardiol ; 109(6): 550-559, Dec. 2017. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887985

RESUMO

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bloqueio Atrioventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Brasil , Fatores de Risco , Eletrocardiografia , Bloqueio Atrioventricular/fisiopatologia
2.
Catheter Cardiovasc Interv ; 89(3): 429-436, 2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061861

RESUMO

OBJECTIVES: This study aimed to compare gender-related differences in outcomes of patients undergoing TAVI over a long-term follow-up period.BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been considered the standard therapy for patients with inoperable or high-risk symptomatic aortic stenosis. The influence of gender-related differences in outcomes of patients undergoing TAVI is currently on debate.METHODS: From January 2008 to January 2015, 819 patients (49% men) underwent TAVI and were included in a multicenter Brazilian registry. Patients were followed-up and clinical outcomes were evaluated according to the updated Valve Academic Research Consortium-2 criteria. RESULTS: Mean follow-up was 497 ± 478 days. Compared with women, men had a lower rate of major or life-threatening bleeding (12.0% vs. 20.6%; HR = 0.57 [95CI% 0.40-0.81]; P = 0.001), and major vascular complications (6% vs. 11.7%; HR = 0.50 [95CI% 0.31-0.82]; P = 0.004). At 30 days, all-cause mortality was lower in men than in women (6.5% vs. 11.5%; P = 0.013), however, cumulative all-cause mortality was similar between groups (25.9% vs. 29.7%, men and women, respectively, HR = 0.92 [95CI% 0.71-1.19]; P = 0.52) over the entire follow-up period. By adjusted Cox regression model, renal function, diabetes, peripheral artery disease, and chronic obstructive pulmonary disease (COPD) remained independently predictors of all-cause mortality...


Assuntos
Estenose da Valva Aórtica , Identidade de Gênero , Pacientes
3.
Arq. bras. cardiol ; 65(4): 313-315, Out. 1995.
Artigo em Português | LILACS | ID: lil-319320

RESUMO

PURPOSE: To evaluate the vasodilation effect of intracoronary isosorbide mononitrate (ISMN) on the coronary arteries, systolic aortic pressure (SAP) and cardiac rhythms. METHODS: Forty patients aged 61 (40-72) years, 30 (75) male, were randomized to receive on a double blind fashion, 20 mg of ISMN or placebo. The two groups had similar baseline characteristics. Quantitative coronary arteriography [by cardiovascular measurement system (CMS)] and SAP were compared before and after ISMN. We also observed the cardiac rhythm. RESULTS: There were no arrhythmias. Reference vessel diameter increased from 2.6 +/- 0.5 mm before to 2.9 +/- 0.4 mm after ISMN and did not change, mean 2.9 +/- 0.5 mm, before and after placebo. There was a difference between ISMN and placebo (p < 0.0001). There was no difference in the SAP change between the two groups, 4.2 +/- 0.7 mmHg with ISMN and 1.8 +/- 0.5 mmHg with placebo (p = NS). CONCLUSION: ISMN promotes a safe and effective vasodilation of the coronary arteries with no major effects in cardiac rhythm and systolic aortic pressure.


Objetivo - Avaliar o efeito do mononitrato-5 de isossorbida (MNIS) sobre as artérias coronárias, pressão arterial sistêmica média (PAS) e ritmo cardíaco, quando injetado intracoronário. Métodos - Quarenta pacientes, idade entre 40 a 72 (média 61) anos, 30 (75%) homens, foram sorteados para receber, de maneira cega, 20mg de MNIS ou placebo (PL). Os dois grupos tinham características basais semelhantes. A angiografia coronária quantitativa (através do sistema CMS - cardiovascular measurement system) a PAS e o ritmo cardíaco foram comparados antes e após a injeção de MNIS/PL. Resultados -Não houve arritmias. O diâmetro coronário variou de 2,6± 0,5mm, antes, para 2,9±0,4mm, após oMNIS, e nuo variou com a injeção de PL, permanecendo 2,9±0,5mm antes e após, havendo diferença significativa entre o MNIS e o PL (p<0,0001). A variação da PAS não foi diferente entre os 2 grupos, sendo 4,2±0,7mmHg no grupo MNIS e 1,85±0,5mmHg no grupo PL (p=NS). Conclusão - O MNIS promove eficaz e segura dilatação coronária, pois não induz à hipotensão arterial sistêmica ou alteração no ritmo cardíaco


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Vasodilatadores , Vasos Coronários , Dinitrato de Isossorbida , Pressão Arterial/efeitos dos fármacos , Dinitrato de Isossorbida , Angiografia Coronária , Injeções Intra-Arteriais , Método Duplo-Cego
4.
Arq. bras. cardiol ; 53(5): 247-250, nov. 1989. tab
Artigo em Português | LILACS | ID: lil-87225

RESUMO

Foram analisados, retrospectivamente, a incidência quanto a sexo e idade, sintomatologia, alteraçöes do segmento ST e da onda T e dos intervalos QT e PR do eletrocardiograma, bem como distúrbio do ritmo cardíaco, em dois grupos de pacientes ambulatoriais: Grupo I (n = 63), com diagnóstico ecocardiográfico de prolapso da valva mitral (PVM) e Grupo II (n = 63), com ecocardiograma normal. Houve predomínio do sexo feminino em ambos os grupos, na proporçäo de 2,5:1 e 1,5:1, respectivamente. As idades variaram entre 15 e 69 anos, com mdia de 29,3 ñ 10,8 anos, no grupo I e entre 9 e 58 anos, com média de 26,5 ñ 10,1 anos, no grupo II. Palpitaçöes, dor precordial, em geral atípica e dispnéia, foram os sintomas mais freqüentes, ocorrendo em 52 casos (82,5%) do grupo I e em 45 (71,5%) do grupo II. As alteraçöes do segmento ST e da onda T ocorreram em apenas dois casos (4%) do grupo I e em oito casos (13%) do grupo II (p > 0,05). O intervalo PR se mostrou igual ou inferior a 0,20 s em todos os casos de ambos os grupos e o QTc estava prolongado em apenas dois casos (4%) do grupo I e em um (1,5%) do grupo II. As taquiarritmias, quando analisadas globalmente, pelo eletrocardiograma convencional, ocorreram em 17 casos (31,5%) do grupo I e em dez casos (16,5%) do grupo II. As extra-sístoles ventriculares ocorreram em 12 casos (22%) do grupo I e em oito casos (13%) do grupo II. Já a taquicardia paroxística supraventricular foi registrada em cinco pacientes (9%) do grupo I e em nenhum caso do grupo II...


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Prolapso da Valva Mitral/fisiopatologia , Frequência Cardíaca , Ecocardiografia , Estudos Retrospectivos , Eletrocardiografia
5.
ACM arq. catarin. med ; 17(4): 221-5, dez. 1988. ilus, tab
Artigo em Português | LILACS | ID: lil-74444

RESUMO

O objetivo deste estudo foi demonstrar a prevalência das manifestaçöes músculo-esqueléticas (MME) e das lesöes ósseas (LO), e a associaçäo existente entre ambas, em pacientes pediátricos comprovadamente portadores de algum tipo de neoplasia. Objetivou-se, também salientar a necessidade de diagnóstico diferencial, na presença destas manifestaçöes, entre neoplasias malignas e outras doenças. Foram analisados 118 pacientes e os resultados obtidos foram os seguintes: näo houve associaçäo entre MME e grupo etário; um número expressivo de pacientes, embora näo a maioria, apresentou alguma MME e/ou LO; houve associaçäo entre MME e LO; a ocorrência de LO; sem MME foi täo freqüente quanto com manifestaçäo; na maioria das vezes em que a MME esteve presente, havia LO associada; o tipo de MME mais encontrada foi a dor localizada; a variedade de LO mais encontrada foi a lesäo osteolítica


Assuntos
Lactente , Pré-Escolar , Criança , Adolescente , Humanos , Masculino , Feminino , Leucemia , Artrite Infecciosa , Edema , Neuroblastoma , Osteomalacia , Osteomielite , Dor , Esclerose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...